As winter heating demand accelerates across Europe, national market surveillance agencies are intensifying compliance inspections on seasonal heating appliances. Under EU Safety Gate Notification No. SR/03181/26 (submitted by Germany), a China-manufactured Elektromax wall-mounted electric heater (identified in marketplace listings as model WJX-668) has been subjected to a formal market withdrawal due to serious electric shock hazards.
Technical files describe the unit as a wall-mounted space heater measuring 550 × 165 × 240 mm without a cooling function, explicitly listing the People's Republic of China as the country of origin. During laboratory compliance audits conducted under the EU Low Voltage Directive (LVD, 2014/35/EU) and harmonized European standard EN 60335, German regulators identified two critical structural safety failures:
Accessible Live Parts via Ventilation Grille: When tested with standardized articulated test probes, live internal high-voltage components were found to be physically accessible through the exterior air ventilation grilles, exposing consumers to direct electrocution hazards;
Ineffective Power Cord Strain Relief: During mechanical pull and torque testing under EN 60335 Clause 25.15, the cord anchorage failed to secure the mains supply cable adequately. External tugging allows the cord to shift or detach from internal terminals, making live wiring accessible to users.
For Chinese OEM/ODM factories in major heating appliance hubs (such as Cixi, Ningbo, and Shunde), this German enforcement notice highlights two pervasive manufacturing pitfalls: first, industrial designers seeking higher airflow or lower acoustic turbulence frequently widen intake/exhaust louver spacing without maintaining sufficient internal recessed clearances from live PTC terminals; second, assembly lines occasionally under-torque strain relief clamps or accept loose injection-molded cord bushings. With European winter enforcement peaking, factories must mandate calibrated IEC 61032 test-probe checks and inline pull-force audits across every production lot to avoid costly EU market withdrawals.